An Investigation of Regional Variations in the Biaxial Mechanical Properties of Porcine Mitral Valve

作者:Candra; Ratna; Sari; Shenda; Chen; Yan...mitralvalveheartbiomechanicalpropertiesleafletchordaetendineae

摘要:Objective Mitral valve(MV)plays an importance role in regulating blood flow from left atrium to left ventricle and preventing backflow to left atrium.Mitral Valve consist of four important parts;anterior leaflet,posterior leaflet,chordae tendineae,and papillary muscles,which all work in harmony.The material properties alteration on the leaflet causes MV malfunction,and leading to valve diseases such as regurgitation and stenosis.The alteration may be caused by several factors such as calcification,genetic disorders,and infection,which usually have an influence to the mechanical properties,and thus affecting the mechanical behavior of MV.In consequence,some of the patients need MV replacement or repair to restore the normal function of MV.The important point for succeeding such a medical treatment depends on the technique,design,and material used in the treatment shall help rebuild the normal mechanical environment and behavior of MV.Therefore,the mechanical and materials characteristics of MV become a magnetism to explore.In this study,we present an integrated experimental and mathematical constitutive study base in collagen distribution aiming at the mechanical property differences in various region on MV.Methods and materials Both the size and composition of porcine valves are similar to human’s,so the porcine heart valve is often being used in experimental research.Mitral valve was isolated from fresh eight porcine hearts(250-500 gr),and perfused in PBS solution to maintain moist.Anterior and posterior leaflets were separated and dissected into 4 part(two 8~*8 mm rough zone and two clear zone samples)and 2 part(8~*8 mm belly and edge of the clear zone)respectively.Tracking markers(glass bean)were stickled on specimen with superglue(cyanoacrylate adhesive).Then,the specimen was mounted onto biaxial tester machine(CeIIScale,Biotester),and the tests are run by force control.During mechanical test,the specimen is immersed into PBS solution in physiological temperature(37℃).Every test procedure contains 8 preco

注:因版权方要求,不能公开全文,如需全文,请咨询杂志社

医用生物力学

《医用生物力学》(CN:31-1624/R)是一本有较高学术价值的大型双月刊,自创刊以来,选题新奇而不失报道广度,服务大众而不失理论高度。颇受业界和广大读者的关注和好评。 《医用生物力学》主要刊登交流我国学者在生物力学研究中取得的成果和部分国外专家的论文。着重刊登对科研与临床实践有指导意义的论著,同时还开辟综述、讲座、经验交流、研究简报、专题讨论等专栏。内容充实,反映了中国生物力学的研究动向和成果。

杂志详情