HI,欢迎来到学术之家,发表咨询:400-888-7501  订阅咨询:400-888-7502  股权代码  102064
0

基于红外热成像技术的复合式温场测温方法

作者:孙坚 富雅琼 杭庆彪 陈乐 Ya-qiong Qing-...红外热成像技术复合式测温方法basedtemperaturefields红外热像仪修正模型测量目标热电偶model位置测量结果标准建立factors准确度重复性修正值吸收率复现性发射率

摘要:针对测量目标发射率和吸收率估计不准确将造成红外热像仪测量温场误差较大的问题,提出了用热电偶作为标准建立红外热像仪修正模型的方法.建立热电偶所在位置的修正模型后,用其修正热像仪在其它位置的测量结果,从而提高了热像仪测量温场的准确度.30~200℃的实验证明其修正值具有较好的重复性和复现性. Abstract: The inaccurate estimation to the emissivity and absorptivity of the measured target is one of the important factors that cause large error for temperature fields measurement using infrared thermal imager. A method for establishing the modified" model for infrared thermal imager is proposed, and the thermocouples are used as a standard. After the model was estabhshed at the point where the thermocouple is placed, it can be used to correct any other point measured by the thermal imager. This method improves the accuracy of temperature fields measurement using thermal imager. It has been proved by experiments that the method has good repeatabihty and reproducibility from 30 ℃ to 200 ℃.

注:因版权方要求,不能公开全文,如需全文,请咨询杂志社

计量学报

《计量学报》(CN:11-1864/TB)是一本有较高学术价值的月刊,自创刊以来,选题新奇而不失报道广度,服务大众而不失理论高度。颇受业界和广大读者的关注和好评。 《计量学报》所刊登的英文文摘为《中国科学文摘》、《中国科技文摘》等收录,中文摘要为《计量测试文摘》、《中国物理文摘》等收录,部分英文摘要还为《EI》收录。